Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. bras. cardiol. invasiva ; 15(4): 363-369, out.-dez. 2007. ilus, tab
Article in Portuguese | LILACS, SES-SP | ID: lil-477835

ABSTRACT

Introdução: Aposição incompleta (AI) é descrita após implante de stents farmacológicos (SF) e pode associar-se à trombose de stents. Em razão de diferentes plataformas, polímeros e fármacos utilizados, diferenças na eficácia e na segurança entre SF também são esperadas. Objetivo: Avaliar a incidência de AI persistente e tardia após implante de stents com sirolimus (SES) e com zotarolimus (ZES) e a evolução dos pacientes que apresentem essa alteração. Método: Análise de 242 pacientes tratados com SF (175 pacientes com SES – Cypher® – e 67 pacientes com ZES – Endeavor™) e submetidos a ultra-sonografia intracoronária após o implante e aos seis meses. Resultados: No grupo tratado com SES, 7 (4%) pacientes apresentaram AI tardia e 12 (6,8%), AI persistente. No grupo tratado com ZES, nenhum caso de AI tardia foi identificado e, em 4 pacientes, observou-se AI após o implante e que desapareceu aos seis meses. Nos pacientes com AI tardia, observou-se aumento evolutivo dos volumes do vaso (de 377,2 ± 148,9 mm3 para 431,9 ± 155,1 mm3; p = 0,51)e da placa (de 206,1 ± 51,5 mm3 para 236,9 ± 68,4 mm3; p = 0,36). O volume de hiperplasia intimal foi maior após ZES (16,6 ± 5,8 mm3 vs. 5,1 ± 5,5 mm3; p < 0,0001). Após nove meses, não ocorreram eventos cardíacos adversos nos pacientes com AI. Conclusão: A incidência de AI tardia foi de 2,9% e observada após SES. A presença de AI não esteve relacionada a eventos adversos a médio prazo.


Background: Incomplete stent apposition (ISA) has been documented after drug-eluting stents (DES) and could be related to stent thrombosis. Because DES differ in metal platform, polymer and pharmacological agent, differences in performance and safety are expected. Objective: We sought to investigate the frequency and clinical consequences of ISA after implantation of sirolimus- (SES) and zotarolimuseluting stents (ZES). Methods: 242 patients (pts) who underwent DES placement (175 pts with Cypher® and 67 pts with EndeavorTM stents) had serial intravascular ultrasound (IVUS) performed (at index procedure and after 6-months). Results: 7 pts (4%) had late-acquired ISA after SES. Another 12 (6.8%) pts treated with SES had persistent ISA. Among pts treated with ZES, none had late ISA and 4 had ISA observed after stent implantation that completely resolved at 6-months. There was an increase in vessel (377.2 ± 148.9 to 431.9 ± 155.1 mm3, p = 0.51) and in plaque volume (206.1 ± 51.53 to 236.91 ± 68.4 mm3, p=0.36) in pts with late ISA. Amount of neointimal hyperplasia was significantly higher in ZES than SES (16.6 ± 5.8 mm3 vs 5.1 ± 5.5 mm3, p < 0.0001). After 9 months, no adverse clinical event was observed in pts with ISA. Conclusion: Overall incidence of IVUS-detected late incomplete DES apposition was 2.9%, all after SES. The presence of ISA was not related to clinical adverse events during mid term follow-up.


Subject(s)
Humans , Female , Pregnancy , Adult , Stents , Coronary Restenosis , Ultrasonics , Heparin/administration & dosage , Incidence , Ticlopidine/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL